Reliable Particle Counter
Airborne Particle Counter (APC) is fully compliant with ISO14644-2015 and ISO21501-4 standard.
Capacitive touch screen8.0″
Zone20,000
Data 5 million sets
Portable 6.1Kg
Product details
Product Feature
8 inch capacitive touchscreen, quick response
Even with two pairs of latex gloves
Sealed 316L stainless steel enclosure and dust plug to prohibit dust and water
Automatically Collect Air Samples
APC data exceed the limit,triggers the BAS to start sampling
Operation Interface
Data
-Standard report: one key to generate ISO/EUGMPI CHINESEGMP reports
-Data review and data export
1. Sum up data by zone.
2.Freely switch counting unit between △/Σ/#,m /ft.
3.Automatically generate UCL values and average values
4.Search for sample records precisely by time,zone and operator.
-Data integrity: featured with audit trail.
Sampling
- Real-time concentration curves, to get a better understanding of environmental particle condition.
- Quick editing function, to make sampling more flexible.
Setup
- Clear layout for orders. Simple and easy to use.
- One-click for system software upgrade.
- Multiple sets of personalized sampling schemes
can be customized for any zone.
WIFI
WIFI is used for data transmission with other devices through wireless network or wired connection.
Wired settings are used for setting the IP address of APC. Set the IP address of wired connection after connecting the APC unit to the network cable. Wired settings are divided into Manual and Auto. See chart 5-3-19. Touch【Manual】icon to set the IP address, input the IP, subnet mask and gateway. Touch【】icon to save the settings. Touch【Auto】icon to obtain the IP address automatically. The contents of IP, subnet mask
and gateway appear gray. Touch【】icon to save the settings.
WIFI settings are used for connecting with the wireless network. Touch【Scan】icon to search the wireless network nearby, select the wireless network need to be connected and enter the password. Touch【Connect】icon to connect to the internet. The icon on the top right corner of the screen means the network is connected. See chart 5-3-20.
When need to connect to the Data Acquisition system of MicronView, enter the IP address of the device. Touch【Connect】icon to connect to the device. See chart 5-3-21.
When need to connect to the FTP server for data transfer, enter the IP address, port, user name, and password of the FTP server in the same LAN. When the IP address is set successfully, the data can be transferred to the destination folder via FTP. See chart 5-3-22.