Sterile Airborne Particle Counter
Airborne Particle Counter (APC) is fully compliant with ISO14644-2015 and ISO21501-4 standard.
Capacitive touch screen8.0″
Zone20,000
Data 5 million sets
Portable 6.1Kg
Product details
Product Feature
8 inch capacitive touchscreen, quick response
Even with two pairs of latex gloves
Sealed 316L stainless steel enclosure and dust plug to prohibit dust and water
Automatically Collect Air Samples
APC data exceed the limit,triggers the BAS to start sampling
Operation Interface
Data
-Standard report: one key to generate ISO/EUGMPI CHINESEGMP reports
-Data review and data export
1. Sum up data by zone.
2.Freely switch counting unit between △/Σ/#,m /ft.
3.Automatically generate UCL values and average values
4.Search for sample records precisely by time,zone and operator.
-Data integrity: featured with audit trail.
Sampling
- Real-time concentration curves, to get a better understanding of environmental particle condition.
- Quick editing function, to make sampling more flexible.
Setup
- Clear layout for orders. Simple and easy to use.
- One-click for system software upgrade.
- Multiple sets of personalized sampling schemes
can be customized for any zone.
SPECIFICATIONS
FLOW RATE: A110: 100LPM±3%
A120: 50LPM±3%
A130: 28.3LPM±3%
SIZE RANGE: A110: 0.5µm-25µm
A120, A130: 0.3µm-25µm
SIZE CHANNELS: A110: 0.5µm, 1.0µm, 2.0µm, 3.0µm, 5.0µm, 10.0µm
A120, A130: 0.3µm, 0.5µm, 1.0µm, 3.0µm, 5.0µm, 10.0µm
SIZE RESOLUTION: <15% @ 0.5µm (meets ISO 21501-4)
COUNT EFFICIENCY: A110: 50% ±20% for 0.5µm, 100% ±10% for >0.75µm (meets ISO 21501-4 and JIS B9921)
A120, A130: 50% ±20% for 0.3µm, 100% ±10%for >0.45µm (meets ISO 21501-4 and JIS B9921)
CONCENTRATION LIMIT: A110: 560,000 particles/ft³at 10% coincidence loss
A120: 840,000 particles/ft³at 10% coincidence loss
A130: 1,400,000 particles/ft³at 10% coincidence loss
ZERO COUNT: <1count/5min
EXHAUST: Internal HEPA filter (>99.997%@0.3µm)
ZONE/ LOCATION: 20,000 rooms and 200,000 locations
SAMPLING TIME: 1 second to 168 hours
CYCLES: 1000 samples on one location
LASER SOURCE: Long life laser
DATA STORAGE: 3.5G, ≥5,000,000 sets of sample records
DISPLAY: 8” LCD capacitive touch screen
LANGUAGE: Chinese, English
DATA RELIABILITY: Compliant with 21 CFR Part 11
REPORTS: Compliant with ISO/EUGMP/CHINESEGMP/Fed Std
CALIBRATION FREQUENCY: Recommend at least once a year
DIMENSIONS (HXWXD): 254x204x263mm
WEIGHT: 6.1Kg (13.45lbs) (without battery)
ENCLOSURE: 316L Stainless Steel
POWER: AC 100-240V, 50 Hz/60 Hz
BATTERY: 10.8V, 9000mAh, rechargeable lithium battery
BATTERY ENDURANCE: A110: running for 4 hours
A120: running for 7 hours
A130: running for 9 hours
MAX POWER: consumption AC 90W
OPERATING CONDITIONS TEMPERATURE:: 5℃-35℃, relative humidity up to 95%
STORAGE CONDITIONS TEMPERATURE: -10℃-40℃, relative humidity up to 98%
SAFETY: EN 61010-1:2010, EN 61326-1:2013, EN 61326-2-2:2013,EN 60825-1:2014, EN 61000-6-1:2007, EN 61000-6-3:2007+A1,FCC Part 15, Subpart B
WARRANTY: 2 years after activation
Data
Title | Description |
Touch【More function】icon to open the extended menu bar. The extended function includes Error RECs, FTP, Print Data, Export PDF, Export DATA and Delete Data. Touch the corresponding function icon to open the function interface. | |
| Add comment function, touch this icon to add a comment to the sample data. After adding successfully, touch【 |
To review the list of error records. The errors consist of flow errors and laser errors. Touch any record to view all the content for that record. When there are more records than shown on the screen, touch the up arrow or down arrow to move up and down the screen. | |
Print the data, touch【OK】icon to preview the contents of the printout slip. Touch【】icon to print. During the process of printing, touch【】icon to stop printing. The data interface in a single room, touch【】icon to set the data ID that needs to be printed, enter “1-5” to print 5 slips which are ID: 1 to ID: 5, enter “1/5” to print out 2 slip which are ID:1 and ID:5. | |
| After successfully connecting to FTP in the WIFI interface, enter the data interface to select the sample data to be transferred, enter the operator ID, and transfer the sample data file to the target folder via FTP. |
Export PDF is used for exporting the sampling period records in the form of PDF file. It can be only exported to a MICRONVIEW USB flash drive. Multiple cycle data can be exported, or can only export one cycle data. When exporting one cycle data, the report title needs to be added. When no title is entered, the export report title defaults to the room name for that cycle. When exporting multiple cycles data, select ‘All in one file’ check box to combine the data into a single PDF file to export; or export to multiple PDF files in the form of one cycle data. One cycle data export report, including sampling data and location mean and statistics (mean, UCL values, SD values, maximum value and minimum value) of the room. Multiple cycles data export report only contains sample data. | |
Export data is used for exporting all of the data as db file, it can only be exported to a MICRONVIEW USB flash drive. | |
【Delete】icon, touch it and the prompt “According to data management, all sample data of this device will be deleted” will pop up, touch【OK】icon to delete. | |
【Search】icon, find the required records via search criteria such as Item number, start/end date, operator, group, zone, alarm and comment. | |
【Return】icon, clear the current content. | |
To generate the standard report compliance with ISO, EUGMP, CHINESEGMP and Fed Std standard report. To analyze if the collected data comply with standard report requirements. Compliant results are judged as pass, otherwise fail. If the sampling condition does not meet the minimum requirements of the standard for the sampling condition, the result is invalid. Touch【】icon, Standards, Class, Status, Air Flow and Largest selected size can be re-selected. Allow to exclude one record. Touch【OK】icon to preview the standard report. Touch【】 icon to print the standard report. | |
ALL | Select “ALL” option on the data interface to export, FTP transfer or print all the data with one click. Deselect “ALL” option, all data is not selected. |
Page | Select “Page” option on the data interface to export, FTP transfer or print all data on the current page. Deselect “Page” option, the current page data is not selected. |